EL460N
Sorry this product has been discontinued
You can contact with us for more information.
Main characteristics
- Electrolysis type: PEM (Proton exchange membrane, caustic free)
- Number of cell stacks: 3
Hydrogen gas production
- Max. nominal hydrogen flow: 477 Nm3/h (1,028 kg/day)
- Hydrogen flow range: 10 – 100%
- Operating pressure: 15 – 40 barg (217-580 psig)
- Hydrogen purity (before gas purification): > 99.9%; < 25 ppm O2; H2O saturated
- Hydrogen purity (after gas purification): 99.999%; < 5 ppm O2; < 5 ppm H2O
Electrical requirements
- Voltage: 3 x 400 VAC ± 10% (3Ph+N) / 3 x 480 VAC ± 10% (3Ph+N)
- Frequency: 50 Hz ± 5% / 60 Hz ± 3%
- Power (BoP + Stacks): 2,392 kW
- Stack consumption: 4.7 kWh/Nm3 H2
- AC power consumption (BoP + stack): 5.1 kWh/Nm3 H2
Feed water – tap water (if water treatment plant is included)
- Consumption: 636 L/h
- Conductivity: < 2,000 uS/cm (T 25 ºC (77 ºF))
- Pressure: 2-6 barg (29-87 psig)
- Temperature: +5 ºC to + 40 ºC (+41 ºF to +104 ºF)
Feed water – demi water (if water treatment plant is not included)
- Consumption: < 1 L/Nm3 H2
- Quality: > 10 MΩcm (< 0.1 uS/cm); TOC < 30 ppb
Control system
- PLC: Fully automated and unattended with 15″ color touch screen
- Communication: Modbus TCP/IP or Profinet (RJ45 port)
Environmental conditions
- Ambient temperature range: +5 ºC to + 45 ºC (+41 ºF to +113 ºF)
- Humidity: 0 to +95% (non-condensing)
- Air ventilation: Available from a non-hazardous area
- Installation area: Indoor/Outdoor
Dimensions and weight
- Dimensions (LxWxH): 2 x [40ft container (12.0m x 2.4m x 2.9m) (39.4ft x 7.9ft x 9.5ft)]
- Approx. weight: 40,000 kg (88,000 lb)
Standards & regulations
- Compliance: CE, ISO 22734-1 / NFPA 2-2016 & NFPA 70
Other characteristics
- Duty cycle: 100% (24/7)
- Start-up time (from stand-by): < 1 sec
- Cold start time: < 5 min
- Nitrogen Supply System: For each purge, consumption is <0.2 kg at 3 barg (to be supplied by the customer).
- Instrumentation air System: Consumption 7 Nm3/h at 10 barg (to be supplied by the customer).
Always included
All our products do always incorporate:
Hydrogen cooling system
Emergency shutdown system
Overpressure relief system
Redundancy on critical safety parameters
Heat management (no cooling water is needed)
Uninterruptible Power Supply (UPS)
Virtual Private Network (VPN) connection
Additional Options
All our products can include:
Oxygen processing system
Hydrogen purification system (SAE J2719 September 2011)
Water treatment system
Extreme environmental conditions package (low and high temp)
Hydrogen Mass Flow Measure & Purity Measure (H2O & O2 Sensors)
Nitrogen System
Instrumentation Air System
Medium Voltage Connection
Heat Recovery System